SUPPORT - MANUALS & DOWNLOADS
Software that captures measurement data

ChromaChecker Uploader

 

Basic features 

  • The ChromaChecker Uploader application can monitor specific folders.
  • Only files with defined extension (.xml  .txt. svf  .csv, cxf .mxf  .lxf)  or with specific  permanent name will be uploaded (select one method per task)
  • Files can be renamed with a current timestamp plus additional prefix if defined.
  • Files from an Input Folder can be copied and or moved (DEL option) to local Output Folder. 
    To activate select Output Folder. 
  • At the same time, files can be transmitted using SOAP protocol to ChromaChecker server
  • Each task has to be Active in order to operate (Active checkbox).
  • The application has an auto-mount feature that will re-establish network connection to remote hosts  (if remote folders are defined).
  • Local IT Administrator may want to lock interface to prevent from unauthorized modification.

 

 

Getting Started

  1. Download the most recent version of the application from ChromaChecker website — installers are available from DOWNLOAD  in the Manual section, execute the installer. 

  2. Go to Admin window and enter SOAP credentials — to confirm click on "Check Connection button" - if your login/password combinations are ok and your subscriptions are valid corresponding information will be displayed. To get SOAP credentials go to SOAP preferences set a password and save it.

     < select




  3. You may want to Lock Admin interface to protect it from unauthorized changes.

  4. Edd new task and define its parameters.

  5. Create next task if required. You may duplicate existing if just small changes have to be applied

Once the task is defined and saved a current status is displayed on the main application window. 
It is important to understand the meaning of icons

 

 

Status Icons

 — task inactive (to activate enter Task "Edit" and select "Active" checkbox)

 — status idle, remote folder is online (normal operation)

 — status active –remote folder is online (normal operation)

 — ERROR, remote folder is offline ( check network connection and automount setting)

 

 

Details of Task edit window - possible options

User may specify various parameters according to needs 

 

 



 

System Log

You may want to check application log - all transmissions should be listed there — if problems occurs an error code list may be useful to understand and resolve an issue. The log file is stored in DataCollector Application Folder. 

The user may want to export Log – Selec folder where Log will be exported. 
Auto Refresh feature can be useful for tracking system activity.

Sample log.

Task Settings:

 

Log:

New file names are created with prefix  "A12" and timestamp
All files are successfully stored Locally and uploaded to destination Track via SOAP connection

 

 

 

Locking Admin interface

For the security reason, an Admin interface can be locked by local IT administrator. 

 

 

 

Saving and restoring configuration

If you want to backup task settings go to Admin window — click on "Save Configuration" button. Be sure that all task are saved before. The file name settings.txt will be stored in the program folder. To restore settings from this file click on "Load Settings" button. The file is human readable and editable - but very basic knowledge is required to do that. 

If you want to upgrade software and restore setting you have to backup first!. Backup doesn't store SOAP credentials. After upgrading you have to re-enter login and password. 

 

 

 

System requirements and software limitations

Application can be launched on most Windows including Windows  XP, Windows 7, Windows 10

 

All required system components: 

  • Microsoft .NET Framework 4 Client Profile
  • Microsoft .NET Framework 4 Extended
  • Microsoft SQL Server 2008 R2 

    if necessary all components will be installed automatically by the Installer.

 

 

 

Troubleshooting

  1. Check SOAP credentials. Click on "Check Connection button in Admin window to confirm

  2. Check Inspectors Status — without valid subscription uploading is not possible

  3. Be sure that your Internet Connection is working properly — check latency and effective speed) - use 3-rd party application to evaluate your Internet connection parameters

  4. Check if both Input Folder and Output Folder exist — when working in the network environment connection with the host may be lost. Check your local network, remote folder, and setting for auto-mount feature

     — if you see this icon means remote folder is offline 

  5. Check potential error codes - if reported in Application Log.

  6. Report an Issue – please remember to attach a settings.txt file, save Log to a separate file. 
    If application crashes describe issue - a sequence of the steps that cause the crash of the application. 

  7. In some cases — when the program is unstable or works in an unexpected way - uninstall it, and install again! 

 

 

 

Legal Notice

Today DataCollector is a free utility only for active ChromaChecker users. It is not allowed to use this software without active Chromachecker account. DataCollector is copyrighted.