SUPPORT - MANUALS & DOWNLOADS
Instrument Inspector Targets

Rotated X-42, B-42 Targets

This manual helps to understand how the user can use any 3-rd party software to scan X-42 or B-42 Targets in landscape position (rotated 90° clockwise).

Most handheld instruments  ( i1Pro 1&2, eXact Scan, Techkon SpectraDens etc) will scan this way.

Some instruments require to start from white ( e.g. eXact), some from the first patch  (i1 Pro) - that why in horizontal position there is a START/STOP WHITE area.

Typical scanning in a horizontal position will capture patches in following order:

first line (A): 36, 31, 25, 19, 13, 7, 1
second line (B): 37, 32, 26, 20, 14, 8, 2
...
last line (F): 42, 36, 30, 24, 18. 12, 6

 

Instrument Inspector for correct patches recognition requires proper CMYK values for all 42 KEY patches:

ID  

C

M

Y

K

1

100.00

100.00

100.00

0.00

2

7.06

1.18

100.00

0.00

3

43.14

30.98

32.16

0.00

4

1.18

38.82

100.00

0.00

5

98.82

25.88

1.18

0.00

6

23.92

100.00

90.98

0.00

7

29.02

1.18

14.12

0.00

8

5.10

98.82

98.82

0.00

9

14.12

12.16

34.12

0.00

10

67.06

100.00

83.92

0.00

11

16.86

1.96

10.98

0.00

12

60.00

9.80

1.18

0.00

13

100.00

83.14

1.96

0.00

14

7.06

23.92

50.98

0.00

15

43.14

100.00

41.18

0.00

16

38.82

23.92

41.96

0.00

17

1.18

70.98

58.04

0.00

18

100.00

87.84

18.04

0.00

19

32.16

1.18

100.00

0.00

20

96.08

90.98

89.80

0.00

21

87.06

34.90

1.18

0.00

22

1.18

89.80

16.86

0.00

23

67.84

1.18

100.00

0.00

24

27.06

10.98

14.12

0.00

25

100.00

49.80

27.84

0.00

26

9.02

3.92

5.10

0.00

27

41.18

83.14

100.00

0.00

28

63.14

1.18

54.90

0.00

29

25.88

61.18

3.14

0.00

30

65.10

52.94

52.16

0.00

31

36.86

20.00

20.00

0.00

32

43.92

85.10

1.18

0.00

33

14.90

1.18

50.98

0.00

34

100.00

49.02

100.00

0.00

35

1.18

25.10

100.00

0.00

36

32.16

7.84

3.14

0.00

37

100.00

72.94

1.18

0.00

38

27.06

27.84

60.00

0.00

39

100.00

1.18

45.88

0.00

40

1.96

40.00

7.84

0.00

41

76.08

83.92

1.18

0.00

42

100.00

1.18

98.04

0.00

 

 

This list has to be reordered according to specific application needs.

 

Additional Infomation

Instrument Inspector Targets have additional control patches and set of 42 KEY patches

For example, X-42 Target has in fact 64 patches — there are 22 additional black or white patches are for control purpose only - the system will ignore them and analyze only 42 key patches. 


Control patches ignored by system (only for ChromaChecker Targets)

  • black patch definition C=0; M=0; Y=0; K=100
  • white patch definition: C=0,39;  M=0;  Y=0;  K=0
  • solid C, solid M, solid Y